Yamaha Grizzly 660 — Yamaha Grizzly 660 User Manual

COOLING SYSTEM * C0NTINUITY BAD CONDITION Replace the thermo switch 2. GOOD CONDITION * 9 - 50 ELEC – + 6.Thermo switch 2 Remove the thermo switch 2 from the ● radiator. Connect the pocket tester (Ω × 10) to the ● thermo switch 2 1. Immerse the thermo switch 2 in coolant 2. ● Check the thermo switch 2 for continuity. ● While heating the coolant use a thermome- ter 3 to record the temperatures. Test step Water temperature Good condition Thermo switch 2 1 Less than 75 ± 3 °C (167 ± 5.4 °F) × 2 More than 75 ± 3 °C (167 ± 5.4 °F) 3* More than 68 °C (154.4 °F) 4* Less than 68 °C (154.4 °F) × Tests 1 & 2; Heat-up tests Tests 3* & 4*; Cool-down tests : Continuity × :

No continuity WARNING Handle the thermo switch 2 with special care. Never subject it to a strong shock or allow it to be dropped. Should it be dropped, it must be replaced. WARNING WARNING R. T.