COOLING SYSTEM * C0NTINUITY * 9 - 49 ELEC – + 4.Fan motor DOES NOT TURN Disconnect the fan motor coupler. ● Connect the battery (12 V) as shown. ● Battery (+) lead → Blue terminal 1 Battery (–) lead → Black terminal 2 Replace the fan motor. Check the operation of the fan motor. ● TURNS OUT OF SPECIFICATION 5.Circuit breaker (fan motor) Remove the circuit breaker from the wire ● harness. Connect the pocket tester (Ω× 1) to the cir- ● cuit breaker. Circuit breaker resistance: Zero Ω at 20 °C (68 °F) Replace the circuit breaker. Replace the circuit breaker. MEETS SPECIFICATION