Electrical system Relays Oil pressure relay - alarm Sensors Note: Sensors are only available with "De Luxe" i nstrument panels. Oil pressure sensor Fig. 122. Oil pressure relay Contact type: Normally open. The contacts close if the oil pressure in the engine drops below 0.3 ± 0.15 bar (4.18 t 2 psi). Note: Checking of the closing point should be conduct- ed with falling pressure. Fig. 125. Oil pressure sensor Resistance testing: Measure with falling pressure and with instrument connected. Measure with ohmmeter class 1 at +20° C (+68°F) Refrigerant temperature relay - alarm Pressure 0 bar (0: 10 +3 /-5 Q 2 bar (27.9 psi): 52 ±4Q 4 bar (55.8 psi): 88 ± 4 Q 6 bar (83.7 psi): 124 ±5Q Fig. 124.
Refrigerant temperature relay Refrigerant temperature sensor i7 Contact type: Normally open. The contact closes if the refrigerant temperature rises over 95°C ± 3°C (203°F ± 5.6°F). Note: Checking of the break point should be conduct- i ng with rising temperature. Fig. 126. Refrigerant temperature sensor Resistance sensor: Measure with the sensor sub- merged to the hexagonal screw for three minutes in cir- culating liquid and with the current switched on. Temp. 60°C (+140°F): 134.0 ±13.5 S2 (t4°C, t7.2°F) 90°C (+194°F): 51.2 ±4.3 Q (t4°C, ±7.2°F) 100°C (+212°F): 38.5 ±3.0 S2 (t40C, t7.20F) 79