Kubota — Cleaning Air Cleaner Primary Element

PERIODIC SERVICE 70 B Cleaning Air Cleaner Primary Element 1. Remove the air cleaner cover and primary element. 2. Clean the primary element: (1) When dry dust adheres to the element, blow compressed air from the inside, turning the element. Pressure of compressed air must be under 205 kPa (2.1 kgf/cm , 30 psi). (2) When carbon or oil adheres to the element, soak the element in detergent for 15 minutes then wash it several times in water, rinse with clean water and dry it naturally. After element is fully dried, inspect inside of the element with a light and check if it is damaged or not. 3. Replace air cleaner primary element: Once every 1000 hours or yearly, whichever comes first.

(1) Grease fitting (Hydraulic lift cylinders pin) A Check to see if the evacuator valve is blocked with dust. (1) Grease fitting (Steering joint shaft) (1) Secondary (safety) element (2) Primary element (3) Evacuator valve (4) Cover (1) Battery terminals