Komatsu — RELIEF VALVE

STRUCTURE AND FUNCTION MAIN CONTROL VALVE RELIEF VALVE 1. Main valve 2. Valve seat 3. Pilot poppet 4. Spring 5. Adjustment screw Function The relief valve is installed to the inlet portion of the main control valve. If the oil goes above the set pressure, the relief valve drains the oil to the tank to set the maximum pressure for the work equipment circuit, and to protect the circuit. Operation ! Port A is connected to the pump circuit and port C is connected to the drain circuit. The oil passes through the orifice in main valve (1), and fills port B. Pilot poppet (3) is seated in valve seat (2). !

If the pressure inside ports A and B reaches the set pressure of pilot poppet spring (4), pilot poppet (3) opens and the oil pressure at port B escapes from port D to port C, so the pressure at port B drops. ! When the pressure at port B drops, a difference in pressure between ports A and B is created by the orifice of main valve (1). The main valve is pushed open and the oil at port A passes through port C, and the abnormal pressure is released to the drain circuit. ! The set pressure can be changed by adjusting the tension of pilot poppet spring (4). To change the set pressure, remove the cap nut, loosen the locknut, then turn adjustment screw (5) to adjust the set pressure as follows.

TIGHTEN to INCREASE pressure LOOSEN to DECREASE pressure 10-92