STRUCTURE AND FUNCTION MAIN CONTROL VALVE Boom and bucket spool at neutral position Operation ! The oil from pump (1) passes through the priority valve, and enters port A. The maximum pressure is set by relief valve (2). ! Bucket spool (3) is at the HOLD position, so the bypass circuit is open and the oil in chamber A passes around the spool and flows to port B. Boom spool (4) is also at the HOLD position, so the bypass circuit is open and the oil in chamber B passes around the spool, enters chamber C of the drain circuit, passes through the filter, and returns to the tank. 10-95