STRUCTURE AND FUNCTION MAIN CONTROL VALVE Bucket spool at DUMP position Operation ! When the work equipment control [ever is pushed, bucket spool (3) is pushed in to the DUMP position. ! The bypass circuit is closed by the spool, so the oil from port A pushes open check valve (7). The oil from port H then flows to the rod end of the cylinder. ! At the same time, the oil at the cylinder bottom flows from port G to drain port C, and returns to the tank. As a result, the bucket is tilted forward. 10-100