STRUCTURE AND FUNCTION ENGINE STARTING CIRCUIT ENGINE STARTING CIRCUIT Function ! A neutral safety circuit is used to prevent the engine ! If the starting switch is turned to the START from starting if the directional lever is not at the N position, current flows from starting switch position. This ensures safety when starting the terminals B - C ц neutral relay terminals 5 - 3 ц engine. starting motor terminal S ц ground, and a circuit is also formed from the battery ц battery relay ц Operation starting motor terminal B , so the engine starts. ! When the directional lever is placed at the N !
If the directional lever is not at the N position, circuit position, the N contacts of the directional lever (1) is not formed, so the engine does not start. switch are closed. ! When the starting switch is turned to the ON position, Electric current flows from battery (+) ц starting switch terminal B - BR ц battery relay. The battery relay is closed, so current flows in the following circuit: (1) battery(+) ц slow blow fuse ц directional switch terminal N ц neutral relay terminals 1 - 2 ц ground, and the relay coil is excited. When this happens, neutral relay terminals 3 - 5 are closed. !
In addition, electric current flows from switch terminal ACC ц Fuel shut-off solenoid ц ground, and then fuel shut-off solenoid pulls the stop lever of fuel injection pump to the full position which sets the operating condition. 10-131