Komatsu — ENGINE STOP CIRCUIT

STRUCTURE AND FUNCTION ENGINE STOP CIRCUIT ENGINE STOP CIRCUIT Function ! The system is equipped with an electrical fuel cut device ( Fuel shut-off solenoid) which makes it possible to start the engine by turning the switch ON or OFF . This improves the ease of operation. Operation ! When the starting switch is turned OFF , starting switch terminals B and ACC are opened. ! The current in the Fuel shut-off solenoid is shut off by the starting switch, so the coil is not excited. Therefore, the stop lever of fuel injection pump is released to the stop position which cuts off the fuel supply to the injection pump and causes the engine to stop. 10-132