Komatsu — KICK DOWN ELECTRIC CIRCUIT DIAGRAM

STRUCTURE AND FUNCTION KICK-DOWN ELECTRIC CIRCUIT DIAGRAM KICK DOWN ELECTRIC CIRCUIT DIAGRAM Normal operation (directional lever at F , speed lever at 2 ) Speed lever set to 2 Directional lever set to F ! When the speed lever is at position 2, no electric ! When the directional lever is set to the F position, current flows to solenoids (2), (3), or (4). In this electric current flows from the battery ѕ Я directional condition, the transmission valve is set to F2 by the lever switch terminal 1 - 2 Я FORWARD relay action of solenoid (1). No current flows to the coil (relay terminal 5 - 6 Я ground.

terminals 5 - 6) of the kick-down relay if the kick-down As a result, the FORWARD relay is actuated and is not pressed. Therefore, the kick-down relay is not terminals 1 and 2 and terminals 3 and 4 are actuated, and the transmission is held in F2. connected. ! Next, the current flows from the battery ѕ Я parking brake safety relay terminal 5 - 3 Я parking brake switch terminal 3 - 2 Я neutralizer relay terminal 1 - 2 Я ground, and neutralizer relay terminal 3 - 5 are Solenoid actuation table connected. In addition, electric current flows from the battery ѕ Я transmission cut-off relay terminal 1 - 2 Я monitor, and transmission cut-off relay terminals 3 - 5 are connected. !

Electric current flows from the battery ѕ Я neutralizer terminal 3 - 5 Я transmission cut-off relay terminal 3 - 5 Я FORWARD relay terminal 1 - 2 Я solenoid 1 Я ground, and solenoid (1) is actuated. 10-142 Solenoid F1 F2 F3 F4 N R1 R2 R3 R4 FORWARD (1) F M F F REVERSE (2) F F F F H-L select (3) F F F F Speed select (4) F F F F