Komatsu — KICK-DOWN SWITCH OPERATED

STRUCTURE AND FUNCTION KICK-DOWN ELECTRIC CIRCUIT DIAGRAM Kick-down switch operated (when operating or traveling in F2 ) (When kick-down switch is pressed ON ) ! When the kick-down switch is pressed, electric In this way, if the kick-down switch is pressed when the current flows from the battery ѕ Я speed lever 2 Я speed lever is at F2 , the transmission will shift to F1. At FORWARD relay terminal 3 - 4 Я kick-down switch the same time, it will be held in F1 by the self-hold Я kick-down relay terminal 5 - 6 Я ground. function of the kick-down relay even when the kick-down As a result, the kick-down is actuated, and kick-down switch is released.

However many times the kick-down relay terminals 1 and 2 and terminals 3 and 4 are switch is pressed, the transmission will stay in F1 . closed. A circuit from kick-down relay terminal 1 - 2 Я kick-down relay terminal 5 - 6 Я ground is formed, so the kick-down relay continues to be actuated even Solenoid actuation table if the kick-down switch is returned. (Self-hold circuit of kick-down relay) ! When the kick-down relay is actuated and terminals 3 and 4 are closed, electric current flows from the battery ѕ Я kick-down relay terminal 3 - 4 Я solenoid 4 Я ground, and solenoid (4) is actuated. Solenoids (1) and (4) are actuated, so the transmission is set to F1 .

10-143 Solenoid F 1 F2 F3 F4 N R1 R2 R3 R4 FORWARD (1) M F F F REVERSE (2) F F F F H-L select (3) F F F F Speed select (4) M F F F