STRUCTURE AND FUNCTION KICK-DOWN ELECTRIC CIRCUIT DIAGRAM Canceling actuation of kick-down switch (case I) (Directional lever moved to N or R ) ! When the directional lever is moved to the R position, ! When the directional lever is moved to the R position, the F terminal contacts are turned OFF, so the electric current flows from the battery ѕ Я directional lever R - Я current stops flowing from the battery ѕ Я directional REVERSE relay terminal 5 - 6 Я ground, so the lever F Я FORWARD relay terminal 5 - 6 Я ground, REVERSE relay is actuated and REVERSE terminals and the FORWARD relay is reset. 1 and 2 and terminals 3 and 4 are closed. ! FORWARD relay terminals 1 and 2 and terminals 3 !
As a result, electric current flows from the battery ѕ Я and 4 are opened, so the electric current stops flowing REVERSE relay terminal 1 - 2 Я solenoid 2 Я - ground, to the solenoid of the kick-down relay, and the kick- and solenoid (2) is actuated. Therefore, only solenoid down relay is reset. (2) is actuated, and the transmission is set to the R2 ! In this way, the self-hold circuit of the kickdown relay position. is canceled, and terminals 3 and 4 are opened, so solenoid (4) is no longer actuated.
(When the Solenoid actuation table directional lever is moved to the N position, the actuation is the same as above and the kick-down relay is canceled.) In addition, FORWARD relay terminal 1 and 2 are opened, so solenoid (1) is no longer actuated. 10-144 Solenoid F1 F2 F3 F4 N R1 R2 R3 R4 FORWARD (1) F F F F REVERSE (2) F M F F H-L select (3) F F F F Speed select (4) F F F F