Komatsu — KICK-DOWN SWITCH OPERATED

STRUCTURE AND FUNCTION KICK-DOWN ELECTRIC CIRCUIT DIAGRAM Canceling actuation of kick-down switch (case II) (Speed lever moved to position other than 2) ! If the speed lever is moved to any position other than 2, the electric current stops flowing from the battery ѕ Я speed lever 2 Я FORWARD relay terminals 3 - 4, and the current to the kick-down relay is also shut off. Solenoid actuation table ! Therefore, the kick-down relay is canceled, and solenoid (4) is no longer actuated. ! If the speed lever is moved to 3, solenoid (3) is actuated. In addition, the directional lever is at the F position, so solenoid (1) is actuated.

Therefore, solenoids (1) and (3) are actuated and the transmission is set to F3. 10-145 Solenoid F1 F2 F3 F4 N R1 R2 R3 R4 FORWARD (1) F F M F REVERSE (2) F F F F H-L select (3) M F F F Speed select (4) F F F F