TESTING AND ADJUSTING MEASURING STALL SPEEDS MEASURING STALL SPEEDS i Measurement conditions C Engine water temperature: Within white range on engine water temperature gauge C Hydraulic oil temperature: 45 - 55 E C (113 - 131 E F) C Engine speed: high idling C Torque converter oil temperature: 60 - 80 E C (140 - 176 E F) Apply the parking brake and put blocks under the tires. When measuring each stall speed, be careful not to touch any rotating part of high temperature part. i Check that low idling and high idling are the standard values.
i Before measuring each stall speed, remove cover ( 1 ) from the speed pickup port, install adapter A2 of tachometer A1 , then connect tachometer A1 and the adapter with a cable. i Check that the engine speed is the standard value. If it is not within the standard range, check for loose linkage or play. TORQUE CONVERTER STALL SPEED i Before starting the operation, check that the tires are chocked and release the parking brake. 1. Start the engine and run at low idling. 2. Place directional lever ( 4 ) at FORWARD or REVERSE, and set speed lever ( 3 ) to the highest position. 3.
Use the brakes to stop the machine, then use multi-tachometer A1 to measure the speed when the engine is run at high idling. i Turn transmission cut-off selector switch ( 2 ) OFF and use the left brake. (Check that the pilot lamp goes out.) i Do not keep the stall condition for more than 20 seconds. Make sure that the torque converter oil temperature does not exceed 120 E C. 20-20