Komatsu — MEASURING STALL SPEEDS

TESTING AND ADJUSTING MEASURING STALL SPEEDS HYDRAULIC STALL SPEED 1. Start the engine and run at high idling. 2. Operate the work equipment control lever ( 4 ), set the cylinder to the stroke end, and activate the work equipment valve relief valve. 3. Use multi-tachometer A1 to measure the engine i Do not keep the stall condition for more than 20 seconds. Operate the control lever quickly. FULL STALL SPEED C Measure the engine speed when the torque converter stall and hydraulic stall are both carried out at the same time. i Before measuring the full stall, check that the torque converter stall and hydraulic stall speeds are normal.

If either of the stall speeds are abnormal, correct the problem and measure again. 20-21