Komatsu — MEASURING AND ADJUSTING WORK EQUIPMENT CONTROL LEVER

TESTING AND ADJUSTING MEASURING AND ADJUSTING WORK EQUIPMENT CONTROL LEVER 2. Adjusting stopper of work equipment control lever (1) Adjusting boom RAISE stopper bolt (10). After connecting the cable, operate the work equipment control lever gradually to the RAISE position and adjust the length of stopper bolt (10) so that stopper bolt (10) contacts the control lever at the point where the control lever suddenly starts to feel heavy. (2) Adjusting boom FLOAT stopper bolt (11).

After connecting the cable, operate the work equipment control lever gradually to the FLOAT position and adjust the length of stopper bolt (11) so that stopper bolt (11) contacts the control lever at the point where the control lever suddenly starts to feel heavy. (3) Adjusting bucket DUMP stopper bolt (12). After connecting the cable, operate the work equipment control lever gradually to the DUMP position and adjust the length of stopper bolt (12) so that stopper bolt (12) contacts the control lever at the point where the control lever suddenly starts to feel heavy. 20-44