TROUBLESHOOTING PRECAUTIONS WHEN CARRYING OUT MAINTENANCE b) Defective compression or soldering of connectors The pins of the male and female connectors are in contact at the compressed terminal or soldered portion, but there is excessive force on the wiring, and the plating peels to cause improper connection or breakage. c) Disconnections in wiring If the wiring is held and tugged and the connectors are pulled apart, or components are lifted with a crane with the wiring still connected, or a heavy object hits the wiring, the crimping compression of the connectors to the wire may be loosened, or the soldering may be damaged, or the wiring may be broken.
d) High pressure water entering a connector The connector is designed to make it difficult for water to enter (drip-proof structure), but if high-pressure water is sprayed directly on the connector, water may enter the connector depending on the direction of the water jet. The connector is designed to prevent water from entering, but if water does enter, it is difficult for it to be drained. Therefore, if water should get into the connector, the pins will be short-circuited by the water, so if any water gets in, immediately dry the connector or take other appropriate action before passing electricity through it.
e) Oil, grease or dirt stuck to connector If oil or grease are stuck to the connector and an oil film is formed on the mating surface between the male and female pins, the oil will not let the electricity pass, and this will cause a defective contact. If there is oil or grease or dirt stuck to the connector, wipe it off with a dry cloth or blow dry with air, and spray it with a contact restorer. i When wiping the mating portion of the connector, be careful not to use excessive force or deform the pins. i If there is water or oil present, it will increase the contamination of the points, so clean with air until all water and oil has been removed. 20-106 WA250-3L