Komatsu — T-18 BOOM DROPS MOMENTARILY WHEN CONTROL LEVER IS OPERATED FROM HOLD TO RAISE

TROUBLESHOOTING T-17, T-18 T-17 Boom shakes during operation When digging or leveling operations are carried out with the boom control lever at HOLD, the bucket and boom move up and down to follow the shape of the ground. Troubleshooting and Cause Measure the hydraulic drift of the boom and check if it is possible to lift the chassis with the boom cylinder. 1. If the hydraulic drift of the boom cylinder is outside the standard value, go to "T-16 Excessive hydraulic drift of boom." 2. If the chassis cannot be raised with the boom cylinder, go to "T-15 Bucket cannot be pushed with boom cylinder." 3.

If the hydraulic drift of the boom is normal, operate the boom several times, and operate the boom cylinder to the end of its stroke. Is it now possible to raise the chassis with the boom cylinder? Yes = Vacuum had formed inside cylinder i However, if this problem appears frequently, the suction valve at the boom cylinder rod end is defective. T-18 Boom drops momentarily when control lever is operated from HOLD to RAISE Checking problem ! When the engine is run at low idling and the boom control lever is operated slowly from HOLD to RAISE, the boom goes down under its own weight. When the lever is operated fully to the RAISE position, the condition returns to normal. Cause !

Defective seating of check valve for boom spool in main control valve 20-179 WA250-3L