Komatsu — TROUBLESHOOTING EAGLE AIR CONDITIONER

TROUBLESHOOTING TROUBLE SHOOTING -EAGLE AIR CONDITIONER TROUBLESHOOTING-EAGLE AIR CONDITIONER 20-267 WA250-3L Troubleshooting Setup: Controller on Temp. 60E F Defrost “off”, Fan on high Abbreviations: EC - Electric Condenser (A) Problem - EO error message display on the controller: Possible Cause Inspection Remedy 1. Open EC power circuit Check the EC circuit breaker for power, voltage, and continuity a) Repair the wiring b) Replace open circuit breaker 2. Defective EC relay (circuit) Check for output voltage on the yellow wire, at the relay coil. Check the voltage and continuity across the relay contacts. a) Repair the connections / wiring b) Replace the defective relay 3.

Open EC voltage detection circuit Check for input voltage on the brown wire, at the controller. a) Repair the wiring or connector 4. Improper wiring installation Applicable to systems without an EC a) See note #3 5. Defective controller Check for output voltage on the yellow wire, at the controller. a) Replace the controller (B) Problem - E1 error message display on the controller: Possible Cause Inspection Remedy 1. Abnormal A/C refrigerant pressure(s). * Cool weather operation may cause low pressure short cycling Check the refrigerant pressures with gauges. High side greater than: 320 psig (R12), or 350 psig (R134a). Low side less than:

3 - 6 psig.* a) Check the condenser operation for air and refrigerant blockage b) Leak check system, repair the leaks and recharge the system c) Relocate the low pressure switch to the evaporator outlet 2. Opened compressor clutch circuit Check for output voltage on the green wire at the compressor. Check the wire connections. Check for continuity across the pressure switch(es) and thermostat. Check the continuity of the clutch solenoid to ground. a) Repair the connections/wiring b) Replace the defective switch(es) or the thermostat c) Replace the defective compressor clutch 3. Opened pressure switch detection circuit Check for an input voltage on the tan wire, at the controller.

a) Repair the connections/ wiring 4. Defective controller Check for output voltage on the green wire, at the controller. a) Replace the controller