Komatsu — TROUBLESHOOTING EAGLE AIR CONDITIONER

TROUBLESHOOTING TROUBLE SHOOTING -EAGLE AIR CONDITIONER 20-268 WA250-3L (B) Problem continued False E1 error message / cold weather charging problems: (Occurs particularly when vapor charging in cold weather) 1. E1 error message may occur during charging when the low pressure switch (LPS) opens at 3 psig. The suction side pressure must rise above 45 psig to reset the E1 error message. 2. When the system is fully charged, the E1 error message should not appear under normal operating conditions. 3. In order to continue charging, by-pass the LPS, turn the controller “off” then “on”, and set the controller to 60E F. This will reset the controller and force into the air conditioning mode. 4.

If the LPS can’t be easily reached, disconnect the clutch wire at the compressor, and run a hot wire directly to the compressor clutch solenoid. Take care not to short out the controller clutch circuit. 5. E1 error message may occur while charging, when the compressor is wired hot. (C) Problem - No Heat Possible Cause Inspection Remedy 1. Opened heat solenoid circuit. Poor connection, loss of voltage. Check for an output voltage on the white wire, at the heat solenoid valve. Check the solenoid continuity to ground. a) Repair connections/wiring 2. Defective heat solenoid or improper installation. Check for coolant blockages in the heat solenoid valve and hoses.