TROUBLESHOOTING TROUBLE SHOOTING -EAGLE AIR CONDITIONER Notes: 1. Wire colors may vary with installation. Refer to the wiring schematic. 2. For 24V controllers, resistor (R17) must be clipped and removed from the circuit board. (Refer to figure below) If the resistor is not clipped on the 24V system, the controller display will light up, but the blower fan will not turn on. 3. For air conditioning systems that do not use an electric condenser, the blue and brown wires must be connected together, on the external harness. The brown wire must be connected to the battery voltage, or the EO error message will result. 4.
Care must be taken during installation, not to pinch or cut wiring from the controller. Shorted wiring may result in damage to the controller. 5. Improper probe location of the evaporator coil thermostat sensor, or ambient cab temperature sensor, may cause short cycling of the compressor. 6. Eagle climate controllers are designed to use normally closed heat solenoid valves. 7. Disconnect the vehicle battery leads, if a machine is to be inactive, or put into storage, for a period of a week or more. The current drain from the controller’s memory may result in a dead vehicle battery.
An optional ignition relay may be installed to disable the controller’s memory function, when the key switch is turned off. 20-270 WA250-3L