DISASSEMBLY AND ASSEMBLY TORQUE CONVERTER, TRANSMISSION Bracket mounting bolt: 279.5 ± 94.5 Nm (28.5 ± 30 kgm) Ъ When installing the rubber, do not use oil or soapy water. Ъ Clearance a : 1.0 - 3.0 mm Mounting bolt: 652.1 ± 34.3 Nm (66.5 ± 3.5 kgm) (Width across flats: 32 mm) Ъ To determine the position of the transmission, adjust with the adjustment screw to set clearance a to the specified dimension, then tighten the mounting bolts. Ъ Check that there is an O-ring fitted in the torque converter housing. Outside circumference of O-ring: Soapy water Ъ When connecting the torque converter to the engine, adjust the height so that the torque converter pilot goes in smoothly.
Do not use force to connect the torque converter and engine. Refilling with oil 1) Tighten drain plug and add transmission oil through oil filler to the specified level. Ъ Run the engine to circulate the oil through the system. Then check the oil level again. Transmission oil: 35 L 2) Tighten the plug at the top of the hydraulic tank filter and the plug in the pump piping, then add hydraulic oil through the oil filler to the specified level. ! Filling with gas Ъ Fill the air conditioner with gas. (Rl34a) Ъ Guideline for amount when filling: 1.5 - 1.6 kg Ъ Before filling with refrigerant, always use the repeat vacuum method to completely evacuate.
Ъ Do not use the can of refrigerant upside down or use any other mistaken method. Be careful not to let liquid Freon get into the refrigerating system. Ъ Do not operate the compressor before charging with refrigerant. Ъ Check that the refrigerant level is correct. Ъ Check the oil level in the compressor. (Specified oil level: 150 +14 -0 cc ND-OIL8) 30-40 WA250-3L