STRUCTURE AND FUNCTION TORQUE CONVERTER OIL FILTER TORQUE CONVERTER OIL FILTER 1. Relief valve 2 Element 3. Center bolt 4. Drain plug Specifications Filter mesh size: 10 microns Filtering area : 8900 cmІ Relief pressure: 0.34 MPa (3.5 kg/cmІ) Operation ! The oil from the torque converter charging pump enters filter inlet port A. It is filtered from the outside of element (2) to the inside, and flows to outlet port B. ! If element (2) becomes clogged with dirt, or the oil temperature is low and the pressure rises at inlet port A, the oil from inlet port A opens relief valve (1) and flows directly to outlet port B in order to prevent damage to the pump or element (2). 10-12