Komatsu — EMERGENCY MANUAL SPOOL

STRUCTURE AND FUNCTION TRANSMISSION CONTROL VALVE EMERGENCY MANUAL SPOOL Function ! If there should be any failure in the electrical circuit and the directional solenoid valve does not work, this spool can be operated manually to engage the FORWARD or REVERSE clutch. Operation 1. Emergency manual spool at neutral ! The oil from the upper valve (pilot reducing valve) passes around emergency manual spool (1), and is blocked by solenoid valves ! When the operating condition is normal, the emergency manual spool is at the neutral position. 2.

Emergency manual spool actuated (FORWARD) When emergency manual spool (1) is pushed in, port a and the drain port are connected, so the oil in chamber b is drained. As a result, directional spool (4) moves to the left in the direction of the arrow, and the oil flows to the FORWARD clutch to engage the clutch. 10-41