Converter Leak Test 6 7 To check the converter for leakage after repair, do the procedure that follows: 8 9 1. Put a plug in the fuel outlet openings. 10 2. Put compressed air in the fuel inlet openings, up to a maximum of 725 kPa (120 psi). 3. Wait ten minutes and then check the converter or fuelock for air leaks. Listen for air to come out around gaskets or seals. IDES106P Carburetor Components (Carburetor Shown Removed For Better Illustration) (6) Spring. (7) Backup plate and diaphragm. (8) Air valve ring. (9) Air-gas valve assembly. (10) Inner carburetor body. 4. If there are no air leaks, then the converter is good. 1.
Remove carburetor cover (3), spring (6), backup plate and diaphragm (7), air valve ring (8) and airgas valve assembly (9). 5. If air does come out, then the converter will have to be disassembled to find the problem. 2. Slowly turn the LP fuel ON at the tank. Recommendation For LP Fuel Systems 3. Check the inlet fuel jet for fuel flow (leakage) in carburetor body (10). In freezing temperature conditions run the engine at fast idle until the engine coolant temperature is between 10 to 16˚C (50˚F to 60˚F). A low idle in cold temperature conditions can damage the engine because of poor circulation of the engine oil.
Running the engine to move the lift truck short distances and then stopping the engine without the coolant being heated can cause the LP fuel to be trapped (cannot be released) in the converter. As this trapped fuel changes to a vapor with the engine stopped, this change causes too much pressure in the converter. The force from the pressure is put on the primary regulator valve against its seat. If this occurs often, the primary regulator valve in the vaporized area of the converter will be damaged. 4. If the operation of fuelock (2) and converter (1) are correct, there will be no fuel flow. 5. If there is fuel flow, the leakage problem must be found either in the fuelock or the converter.
6. Push in primer button (4) on the converter to open the converter fuel regulator valve. 7. A small amount of fuel will flow through the carburetor inlet fuel jet as the fuel from fuelock (2) flows out of the hose. 8. If the operation of fuelock (2) is correct, the fuel flow will stop as soon as the system is empty. G424 Service Manual LPG Fuel System 80