LP Converter - Check, Clean Test LP-Gas Converter 1. Obtain a test kit. 2. Start engine. 3. Close the liquid outlet valve in the fuel storage container. 4. Run engine out of fuel. 5. Install the 0-30kPa (0-5 psi) gauge in the primary test port. Secondary Test Port Primary Test Port 6.. Install the 0-2.5kPa (0-10 in H 2 O) gauge in the secondary test port. LP-Gas Converter 7. Slowly open the liquid outiet valve in the fuel storage container. Inspect Converter for Oil Accumulation 8. Start the engine. 1. Start engine. 9. Operate the engine at idle, part throttle and full load. 2. Close the liquid outlet valve in the fuel storage container 10. Observe readings on both gauges. 3.
Run engine out of fuel. 11. The primary gauge reading should be approximately 10.3kPa (1.5 psi). 4. Remove the regulator secondary cover. 12. The secondary gauge should read approximately negative0.1kPa (0.5 in H 2 O) to negative 2.5kPa (10 in H 2 O). 5. Remove secondary diaphragm. 6. Remove any concentrations of oil from the secondary chamber with soap and warm water. 7. If required, replace them with LP converter service kit. 13. If readings are out of specification, as required. 8. Apply anti-seize compound to screw threads. 9. Re-assemble regulator in reverse order. 10. Slowly open the liquid outlet valve in the fuel storage container. 11. Start engine. 12. Perform leak test.
G424 Service Manual LPG Fuel System 81