LP Converter chamber and the primary atmospheric chamber (18) This causes the primary diaphragm and lever assembly (9) to pivot (10) against primary spring (3) pressure, raising primary valve pin (11), closing off the primary valve (2). Since fuel pressure falls from tank pressure, a liquid liquefied petroleum gas evaporates. As this phase change occurs the fuel takes on heat from the primary heat exchanger chamber of the regulator (4). This heat is replaced by engine coolant, which is piped through passage (12) in the heat exchanger section of the regulator. Fuel will not flow through the regulator to the carburetor until a negative pressure signal is received.
When the engine is cranking or running, a negative pressure signal is generated by the carburetor. This negative pressure signal is communicated to the fuel outlet (13) and the regulator secondary vacuum chamber (14). The negative pressure signal acts upon the lower side of the secondary diaphragm (15) causing a pressure / force imbalance across the diaphragm between the secondary vacuum chamber (14) and the secondary atmospheric vent chamber (16). When the negative pressure signal reaches negative setting value the pressure force imbalance overcomes the secondary spring force (8) and the secondary diaphragm (9) moves downward.
As the secondary diaphragm moves it causes the secondary lever (l7) to pivot and lift the secondary valve (7) off its seat allowing fuel to flow from the primary heat exchanger chamber (4) through the secondary chamber (14) and to the carburetor. Since fuel has now exited the primary heat exchanger chamber (4) the pressure in the chamber will drop, allowing the primary valve (2) to re-open. Whilst fuel is flowing, the calibrated secondary spring (8) will maintain a relatively constant pressure in the secondary vacuum chamber (14) and the amount of fuel flowing will vary depending on how far the secondary valve (7) opens in response to the negative pressure signal generated by the carburetor.
For closed loop control, the secondary atmospheric vent chamber (16) is connected to AVV via a fuel control valve, thus varying the secondary vacuum chamber pressure (14) in response to a pulse width modulated signal provided to the fuel control valve. 15 14 16 8 17 7 1 2 13 11 3 10 9 6 5 12 18 1. Fuel inlet 2. Primary valve 3. Primary spring 4. Primary heat exchanger chamber 5. Pressure transfer port 6. Primary diaphragm chamber 7. Secondary valve 8. Secondary spring 9. Primary diaphragm 10. Primary pivot 11. Primary pin 12. Coolant passage 13. Fuel outlet 14. Secondary vacuum chamber 15. Secondary diaphragm 16. Secondary atmospheric vent chamber 17. Secondary lever 18.
Primary atmospheric chamber Fuel (Propane Liquid), at tank pressure enters the regulator through the fuel inlet port (1). Propane liquid then flows through the primary valve (2), which is held normally open by the primary spring (3), and into the primary heat exchanger chamber of the regulator (4). A small transfer port (5) connects the primary heat exchanger chamber and the primary diaphragm chamber(6). The secondary valve (7) at the outlet of the primary heat exchanger chamber (4) is held normally closed by the secondary spring (8). Therefore the pressure in the primary heat exchanger chamber (4) and the primary diaphragm chamber (6) begins to rise from atmospheric pressure.
When the pressure in the primary heat exchanger chamber (4) and primary diaphragm chamber (6) reaches setting value it causes a pressure/force imbalance across the primary diaphragm (9) between the primary heat exchanger G424 Service Manual LPG Fuel System(Low Emission Version) 91