Vacuum Switch (MAP) Vacuum Switch 1 2 3 1. Electrical 2. Vacuum port 3. Main body 1. Electrical 2. Vacuum port 3. Main body The vacuum switch is a simple direct acting contact pressure switch, consisting of a main body (3), an electrical connector with two pins (1) and a vacuum port connection (2). The unit is normally open (i.e. the electrical connectors (1) are not common) when no vacuum is applied to the vacuum port (2). When vacuum is applied to the port (2) unit respponds and closes the electriccal contacts (1) so that current may pass.
The vacuum switch is a simple diaphragm unit, consisting of a main body (3) housing a diaphragm/spring, two electrical connectors (1) and a vacuum port connection (2). The unit is normally open (i.e the electrical connectors (1) are not common) when no vacuum is applied to the vacuum port (2). When vacuum is applied (see specification for limits) to the port (2) the diaphragm/spring in the body (3) responds and closes the electrical contacts (1) so that current may pass. G424 Service Manual LPG Fuel System(Low Emission Version) 90