daewoo G20E-3, G25E-3, G30E-3 — Daewoo G20E-3, G25E-3, G30E-3 — спецификация (EN)

Engine Control Unit (ECU) 6EV2149 In order to obtain maximum emission reductions from the exhaust gas catalyst, accurate control of the engines operating air fuel ratio (AFR) is required. The engine control unit (ECU) uses input from three sources: excess oxygen information from the exhaust gas oxygen sensor (EGO), ignition pulses (engine RPM) and intake manifold pressure (high or low). This input is used to apply a duty cycle and a rate of change of that duty cycle to the fuel control valve (FCV). The duty cycle of the FCV has a direct effect on the AFR metered by the carburetor and burned by the engine.

ECU algorithms are calibrated for a balance of optimal engine emissions, drive-ability, power and fuel consumption. Within the ECU closed-loop algorithms there are two sets of calibration tables, one for high and one for low manifold pressure. The proper table is selected based on the input from the mechanical calibration of the manifold pressure switch used. Each of the two tables contains sixteen columns corresponding to sixteen engine RPM operating ranges. The proper column is selected based on engine rpm. These columns each have eight calibrations that affect the rate of duty cycle change and allow duty cycle stepping after EGO voltage crosses the .5 V threshold.

The duty cycle stepping is used for AFR biasing and for rapid recovery during transient operation. EGO voltage and time since last EGO switch (across the .5 V threshold) determine the column calibration to apply to the rate of duty cycle change. There are additional calibrations for FCV duty cycle at cold EGO startup and for the number of ignition inputs per engine revolution. During operation a normal sequence of events is as follows: If the EGO voltage is below .5 V, considered a lean condition, the controller steps FCV duty cycle to a lower value, then begins decreasing the FCV duty cycle at a constant rate.

This decreases the flow of air valve vacuum (AVV) through the FCV to the secondary reference chamber of the fuel pressure regulator (sometimes referred to as a vaporizer). This vacuum is depleted at a relatively constant rate via a vent orifice referenced to atmospheric pressure, resulting in a pressure balance proportional to FCV duty cycle and vent orifice size. The lower flow through the FCV results in a higher overall chamber Pressure. Which results in a higher fuel pressure to the carburetor and a richer AFR.

If the duty cycle continues to lower longer than a calibrated number of engine revolutions without an EGO switch, a different calibration is selected resulting in higher rate of duty cycle change until EGO switch. The calibration tables determine the step size, rate of duty cycle change and the number of engine revolutions without an EGO before going to higher rate. If the EGO voltage is above .5 V, considered a rich condition, the controller steps FCV duty cycle to a higher value, then begins increasing the FCV duty cycle at a constant rate. This increases the flow of AVV through the FCV to the secondary reference chamber of the fuel pressure regulator.

The higher flow through the FCV results in a lower overall chamber pressure, which results in a lower fuel pressure to the carburetor and a leaner AFR. If the duty cycle continues to lower longer than a calibrated number of engine revolutions without an EGO switch, a different calibration is selected resulting in higher rate of duty cycle change until EGO switch. The calibration tables determine the step size, rate of duty cycle change and the number of engine revolutions without an EGO before going to higher rate. G424 Service Manual LPG Fuel System(Low Emission Version) 93