LP Converter-Check, Clen Inspection of Vacuum Switch See, “LP Converter-Check, Clean” in LP Fuel System Section. Inspection of Fuel Lock - Off 6EN2132 1. Connect a hand vacuum pump to the nipple of the vacuum switch. 6EN2135 2. Using a vacuum pump, vacuum (0.7 or more kPa) is applied to a vacuum sensor, and the existence of continuity between sensor terminals is checked. 1. When voltage is impressed to the terminal of fuel lock-off, check whether there si operation sound. 2. If there is an abnormality, replace the fuel lock-off. Inspection of Fuel Control Valve 1. Connect a hand vacuum pump to the nipple A of the vacuum switch. 3. If there is an abnormality, replace the vacuum switch.
Inspection of Vacuum Switch (MAP) 6EN2131 6EN2133 2. Battery voltage is impressed between the terminals of a fuel control valve, a hand vacuum pump is connecting in nipple A, and vacuum is applied. 1. Connect a hand vacuum pump to the nipple of the vacuum switch. 2. Using a vacuum pump, vacuum (24 or more kPa) is applied to a vacuum sensor, and the existence of continuity between sensor terminals is checked. 3. If there is an abnormality, replace the fuel control valve. 3. If there is an abnormality, replace the vacuum switch.
G424 Service Manual LPG Fuel System(Low Emission Version) 97 Vacuum gauge Continuity Not applied Non-conductive 0.7 kPa or more Conductive Items When B nipple is closed When current is flowing Vacuum is felt with a finger. When Current is not flowing Vacuum is not felt with a finger. Vacuum gauge Continuity Not applied Non-conductive 24 kPa or more Conductive