eng — CHANGE OF IN CONVEYOR MOTOT MACHINERY CASE

. MAINTENANCE SERVICE PROCEDURE CHANGE OF OIL IN CONVEYOR MOTOR MACHINERY CASE WARNING A container of capacity over 2.5 liters (0.66 US gal) to receive drained oil 4 - 78 The oil is at high temp erature immediately after the machi ne has been operated. Wait for the oil to cool down before starting the operatio NOTICE For replacing oil in the conveyor motor machinery case, p repare a suitable scaffold for safety and commence the work [AG L height of convey or motor machinery case: 3.0 m (9 R eplacement am ount of oil 2.5 l iters (0.66 US ga 1. Set the containe r under the drain p lug (P). 2. Unscrew drain p lug (P) to drain oil, and tighten it after draining.

The specified dr ain plug tightening torque is 29.4 ± 9.81 N ·m (3 ± 1 kgf·m, 21.7 ± 7.2 lbft) 3. Unscrew oil filler (F) cap and add o il through the oil filler port to the specified a mount. (When oil is supplied to the specified level reaches two-thirds as high as the case (F) cap. oil i s supplied to the specified amount, the oil ceiling) case 4. Tighten oil filler