hitachi — PREPARATION FOR PERFORMANCE TESTS

OPERATIONAL PERFORMANCE TEST / Component Test Adjustment of Main Pump Flow Rate Control The flow rate control is performed by signal current (I) of pump control solenoid valve. The flow rate control is adjusted by changing the set-force of spring (1). Adjustment: Loosen nut (2) and turn adjusting screw (3). T16J-04-04-006 NOTE: Change in Flow Rate (Reference) Pump Speed: 1882 min -1 Adjusting Screw Turn 1/4 Flow Rate Change 54.4 L/min Q Flow Rate Control I Flow Rate Decrease Flow Rate Increase 3 W107-02-05-129 NOTE: I: The signal current of pump control sole- noid valve. T4-5-19 1 2 3