OPERATIONAL PERFORMANCE TEST / Component Test Adjustment of Max. Flow Rate and Min. Flow Rate The flow rate is adjusted by changing the servo piston max. stroke. Adjustment of max flow rate. Loosen nut (2) on the large chamber side end of the servo piston and turn adjusting screw (1). Adjustment of min. flow rate. Loosen nut (3) on the small chamber side end of the servo piston and turn adjusting screw (4). NOTE: Illustration shows the main pump. NOTE: Change in Flow Rate (Reference) Main Pumps 1 and 2 Speed: 1882 min -1 Fan Pump Seed: 1750 min -1 T1JB-04-05-002 Adjustment of Max. Flow Rate Q W107-02-05-129 I Flow Rate Decrease Flow Rate Increase W107-02-05-129 I NOTE: I:
The signal current of pump control sole- noid valve. T4-5-18 3 2 4 1 1 Adjusting Screw Turn 1/4 9.6 L/min 2.8 L/min Flow Rate Change (Main Pumps 1 and 2) Flow Rate Change (Fan Pump) Flow Rate Flow Rate Decrease Increase Adjustment of Min. Flow Rate Q