OPERATIONAL PERFORMANCE TEST / Component Test TRAVEL MOTOR DRAINAGE Summary: 1. While rotating the travel motor with the track to be measured jacked up, measure amount of oil draining from the travel motor and check travel motor performance. 2. During measuring check in order to prevent per- sonal injury. 3. Judge travel motor performance from the results including travel speed, mistrack and so on over- all. 4. The amount of drain oil from the travel motor will change depending on hydraulic oil temperature. Preparation: 1. Main hydraulic oil temperature at 50 ± 5 ° C (122 ± 41 ° F). Rotate the travel motor and warm inside of the motor. 2. Stop the engine.
Push air bleed valve (1) on top of the hydraulic oil tank and release any remain- ing pressure. 3. Disconnect the drain hose in the travel motor at the travel motor end. Install plug (ST 6637) to the disconnected end. Connect test drain hose (3/4-16UN) to the travel motor. Drain Hose M183-01-001 : 27 mm Test Drain Hose : 93 N x m (9.5 kgf x m, 70 lbf x ft) Preconditions for Measurement: 1. Measurement conditions are as below. T157-05-04-019 T183-04-04-011 T4-5-24 Engine Control Dial Power Mode Switch Work Mode Auto-Idle Switch Fast Idle HP Mode Digging Mode OFF Drain Ho se ST