OPERATIONAL PERFORMANCE TEST / Adjustment Push to display Pump 2 Regulator Learning Condition and Pump 1 &2 Regulator Learning Status reversely (black). Push Start. If pump learing has been executed, 1Su or 1Fa (2Su or 2Fa) is displayed reversely (black). Display Item Selection Screen Monitor Screen NOTE: Explanation of Display Item Pump Regulator Learning Switch Display the part shifted by the learning switch reversely (black). Pump 1 Regulator Learning Condition, Pump 2 Regulator Learning Condition Display the condition after learning. (Refer to T4-6-6.) Pump 1 & 2 Regulator Learning Status 1In, 2In:
After replacing MC and when the pump learning has not been executed, these are displayed reversely (black). 1Su, 2Su: If the former learning succeeded, these are displayed reversely (black). 1Fa, 2Fa: If the former learning failed, these are displayed reversely (black). 1Le, 2Le: If the learining is exected now, these are displayed reversely (black). T4-6-4 Select item Pump 2 Regulator + Learning Condition + Pump 1&2 Regulator Learning Status + Pump 1 Regulator Valve Current + Pump 2Regulator Valve Current 4 Start Clear ESC P Reg. Learn. SW OFF ON P1Reg. Press. L Cond. Learnable P2Reg. Press. L Cond. Learnable P1&2 Reg. Press. L. St.
1In 1Su 1Fa 1Le 2In 2Su 2Fa 2Le HOLD ESC 1In 1Su 1Fa 1Le 2In 2Su 2Fa 2Le