OPERATIONAL PERFORMANCE TEST / Adjustment 4. Turn the learning switch in rear console to the ON position. ON Learning Switch OFF 5. After 40 seconds, the monitors below are displayed on the Dr. ZX monitor. After the learning succeeds, turn the learning switch to the OFF position. If the learning fails, refer to the next page and the cause is solved. Execute the learning again. Upper Surface Side EX) Success P Reg. Learn. SW OFF ON P1Reg. Press. L Cond. Learnable P2Reg. Press. L Cond. Learnable P1&2 Reg. Press. L. St. HOLD ESC EX) Failure P Reg. Learn. SW OFF ON P1Reg. Press. L Cond. Low EngSpeed P2Reg. Press. L Cond. P1&2 Reg. Press. L. St. Low EngSpeed HOLD ESC IMPORTANT:
After the learning, turn the learning switch to the OFF position and check the learning status by using Dr. ZX. Start the engine again, and check operation and performance. T4-6-5 E 1In 1Su 1Fa 1Le 2In 2 Su 2Fa 2Le 1In 1Su 1Fa 1Le 2In 2 Su 2Fa 2Le