hitachi — PREPARATION FOR PERFORMANCE TESTS

OPERATIONAL PERFORMANCE TEST / Adjustment Remedy for Failure of Pump Learning IMPORTANT: When the learning fails, check the status with the learning switch ON. When the learning switch is turned OFF to ON, the learning status detected during the learning is deleted and “Learnable” is deiplayed. Learning Switch ON OFF Upper Surface E Side EX) Failure Display Item (Learning Status) T4-6-6 Display Item (Learning Status) Cause Remedy Low Eng Speed • Actual engine speed • Execute failure-diagnosis by using Dr. ZX. (Refer to the Troubleshooting group.) • Monitor actual engine speed and increase engine speed beyond 1600 min-1. Gate Lock Awaked − Move the pilot shut-off lever to the LOCK position.

Signal Over Range • Faulty pump regulator pressure sensor or faulty harness • Faulty pump control solneoid valve or faulty harness • Execute failure-diagnosis by using Dr. ZX. (Refer to the Troubleshooting group.) • Monitor pump regulator pressure by using Dr. ZX and check if pressure is betweeen 0.44 Mpa and 1.96 Mpa. • Check if the harness is open or shorted circuit. • Replace the pump regulator pressure sensor and pump control solenoid valve. Save Failed Faulty MC If saving fails when repeating the learning more than threee times, replace MC. Learnable Noraml − P Reg. Learn. SW OFF ON P1Reg. Press. L Cond. Low EngSpeed P2Reg. Press. L Cond. Low EngSpeed P1&2 Reg. Press. L. St.