TROUBLESHOOTING / Troubleshooting A T5-6-30 Fault Code Trouble Cause 1077-2 CPU Fault Sub-CPU detects main CPU fault in 100 msec after key switch ON. (Sub-CPU resets CPU.) 1079-2 Voltage Fault in 5-V Power Supply 1 5-V 1 power supply voltage: 5.5 V or more, 4.5 V or less 1080-2 Voltage Fault in 5-V Power Supply 2 5-V 2 power supply voltage: 5.5 V or more, 4.5 V or less 1239-1 No Pump Pressure Feed (First Stage) Actual rail pressure lower than target rail pressure for 10 MPa or more holds 8 seconds or more. Or pressure feed indication is limit +1 °C or less, and actual rail pressure lower than target rail pressure for 10 MPa or more holds 8 seconds or more.
1240-1 No Pump Pressure Feed (Second Stage) Actual rail pressure lower than target rail pressure for 10 MPa or more holds 8 seconds or more, when judgment of “No pump pressure feed (first stage)” is completed. Or pressure feed indication is limit +1 °C or less, and actual rail pressure lower than target rail pressure for 10 MPa or more holds 8 seconds or more. 1347-0 PCV1 Open Circuit or Ground Short PCV1 monitor signal is fixed to Low-side. 1347-4 PCV1+B Short Circuit PCV1 monitor signal is fixed to High-side. 1348-0 PCV2 Open Circuit or Ground Short PCV2 monitor signal is fixed to Low-side. 1348-4 PCV2+B Short Circuit PCV2 monitor signal is fixed to High-side.
1485-2 Main Relay System Fault Main relay voltage is 1 V or less. In spite of relay OFF command, relay is connected. 10001-3 EGR Position Sensor Fault (Brushless Specification) EGR position output signal is abnormal. 10002-2 EGR Valve Control Fault Difference between target valve lift and actual position is more than 20 %.