hitachi — PREPARATION FOR PERFORMANCE TESTS

TROUBLESHOOTING / Troubleshooting A T5-6-32 Fault Code Trouble Cause 10003-2 Injection Nozzle Common 1 Drive System Fault No injector 1, 2, 3 monitor input signal exists. 10004-2 Injection Nozzle Common 2 Drive System Fault No injector 4, 5, 6 monitor input signal exists. 10005-1 Charge Circuit Fault (Bank 1) When charge circuit bank 1 voltage inside ECM is low. 10006-1 Charge Circuit Fault (Bank 2) When charge circuit bank 2 voltage inside ECM is low. 10007-2 CPU Monitoring IC Fault RUN-SUB pulse does not change for 20 msec or more. 10008-2 A/D Conversion Fault A/D conversion failure 10009-2 Voltage Fault in 5-V Power Supply 3 5-V 3 power supply voltage:

5.5 V or more, 4.5 V or less 10010-2 Voltage Fault in 5-V Power Supply 4 5-V 4 power supply voltage: 5.5 V or more, 4.5 V or less 10011-2 Voltage Fault in 5-V Power Supply 5 5-V 5 power supply voltage: 5.5 V or more, 4.5 V or less 10013-2 EEPROM Fault EEPROM is faulty.