TROUBLESHOOTING / Troubleshooting A MC FAULT CODE 11101 Fault Code Trouble Cause 11101-3 Abnormal Engine Control Dial Sensor High Voltage Voltage: 4.75 V or higher 11101-4 Abnormal Engine Control Dial Sensor Low Voltage Voltage: Less than 0.25 V Check if harnes between terminal #D15 of harness end of connector MC-D in MC and terminal #2 in switch panel is open or shorted. Faulty MC. YES Faulty harness between MC and engine control dial. YES Disconnect connector of switch panel. Check if voltage between terminals #1 and #3 of harness end of connector is 5 ± 0.5 V. Disconnect connector of switch panel.
Check fi resistance between terminals #1 and #3 of switch panel end of connector is 5 ± 0.5 k Ω . Insert a probe of tester from the back of connector in terminal #2 with switch panel connector connected. When rotating engine control dial, chack if voltage becomes specification. NO YES Check fi voltage between terminal #1 of harness end of connector in switch panel and machine is specification. Open circuit in harness between MC and engine control dial (terminal #3). YES · Key switch: ON NO Open circuit in harness between MC and engine control dial (terminal #1). · Key switch: ON · Specification: 5 ± 0.5 V NO NO Faulty engine control dial. · Specification: Refer to the table below.
Specification of Engine Control Dial Connector (Harness end of connector viewed from the open side) MC Connector MC-D T183-05-04-009 Switch Panel #C15 #3 #1 #2 T5-6-65 Slow Idle 0.3 to 1.0 V Fast Idle 4.0 to 4.7 V