TROUBLESHOOTING / Troubleshooting A PUMP FAILURE MC FAULT CODE 11200 Faulty harness between MC and pump 1 delivery pressure sensor. Check if harnes between terminal #C3 of harness end of connector MC-C in MC and terminal #2 in pump 1 delivery pressure sensor is open or shorted. YES YES Disconnect connector of pump 1 delivery pressure sensor. Check fi voltage between terminals #1 and #3 of harness end of connector is 5 ± 0.5 V. NO Check fi voltage between terminal #1 of harness end of connector in pump 1 delivery pressure sensor and machine is specification. · Key switch: ON · Refer to the table upward. YES Open circuit in harness between MC and pump 1 delivery pressure sensor (terminal #3).
Switch pump 1 delivery pressure sensor with pump 2 delivery pressure sensor and retry. Check if fault code is switched. · Key switch: ON NO Open circuit in harness between MC and pump 1 delivery pressure sensor (terminal #1). NO Faulty pump 1 delivery pressure sensor. YES Connector (Harness end of connector viewed from the open side) Pump 1 Delivery Pressure Sensor MC Connector MC-C #C3 C23 C31 T1J1-05-06-002 T5-6-66 Fault Code Trouble Cause 11200-3 Abnormal Pump 1 Delivery Pressure Sensor High Voltage Voltage: 4.75 V or higher 11200-4 Abnormal Pump 1 Delivery Pressure Sensor Low Voltage Voltage: Less than 0.25 V Faulty MC. NO C1 C10