hitachi — PREPARATION FOR PERFORMANCE TESTS

TROUBLESHOOTING / Troubleshooting A MC FAULT CODE 11202 Fault Code Trouble Cause 11202-3 Abnormal Pump 2 Delivery Pressure Sensor High Voltage Voltage: 4.75 V or higher 11202-4 Abnormal Pump 2 Delivery Pressure Sensor Low Voltage Voltage: Less than 0.25 V Faulty harness between MC and pump 2 delivery pressure sensor. Check if harnes between terminal #C12 of harness end of connector MC-C in MC and terminal #2 in pump 2 delivery pressure sensor is open or shorted. YES YES Disconnect connector of pump 2 delivery pressure sensor. Check fi voltage between terminals #1 and #3 of harness end of connector is 5 ± 0.5 V.

NO Check fi voltage between terminal #1 of harness end of connector in pump 2 delivery pressure sensor and machine is specification. YES Open circuit in harness between MC and pump 2 delivery pressure sensor (terminal #3). Switch pump 1 delivery pressure sensor with pump 2 delivery pressure sensor and retry. Check if fault code is switched. · Key switch: ON NO Open circuit in harness between MC and pump 2 delivery pressure sensor (terminal #1). · Key switch: ON · Refer to the table upward. NO YES Faulty pump 2 delivery pressure sensor.

Connector (Harness end of connector viewed from the open side) Pump 2 Delivery Pressure Sensor MC Connector MC-C #C12 C23 C31 T1J1-05-06-002 T5-6-67 Faulty MC. NO C1 C1