TROUBLESHOOTING / Troubleshooting A PILOT FAILURE MC FAULT CODE 11301 Faulty harness between MC and pressure sensor. Check if harnes between terminal #D16 of harness end of connector MC-D in MC and terminal #2 in pressure sensor is open or shorted. YES YES Disconnect connector of pressure sensor. Check fi voltage between terminals #1 and #3 of harness end of connector is 5 ± 0.5 V. Open circuit in harness between MC and pressure sensor (terminal #3). Switch pressure sensor with other pressure sensor and retry. Check if fault code disappears. Faulty MC. NO NO · Key switch: ON Check fi voltage between terminal #1 of harness end of connector in pressure sensor and machine is specification.
YES NO · Key switch: ON · Refer to the table upward. NO Open circuit in harness between MC and pressure sensor (terminal #1). Faulty pressure sensor. YES Connector (Harness end of connector viewed from the open side) MC Connector MC-D Pilot Pressure Sensor (Swing) #D16 T1J1-05-06-001 T183-05-04-009 T5-6-68 Fault Code Trouble Cause 11301-3 Abnormal Swing Pilot Pressure Sensor High Voltage Voltage: 4.75 V or higher 11301-4 Abnormal Swing Pilot Pressure Sensor Low Voltage Voltage: Less than 0.25 V