TROUBLESHOOTING / Troubleshooting A MC FAULT CODE 11303 Connector (Harness end of connector viewed from the open side) Pilot Pressure Sensor (Arm Roll-In) MC Connector MC-C C1 C10 #C23 C23 C31 T1J1-05-06-001 T5-6-70 Fault Code Trouble Cause 11303-3 Abnormal Arm Roll-In Pilot Pressure Sensor High Voltage Voltage: 4.75 V or higher 11303-4 Abnormal Arm Roll-In Pilot Pressure Sensor Low Voltage Voltage: Less than 0.25 V Check if harnes YES Faulty harness between between terminal #C23 MC and pressure sensor. of harness end of YES connector MC-C in MC and terminal #2 in pressure sensor is Faulty MC. open or shorted. Disconnect connector NO of pressure sensor.

Check fi voltage NO between terminals #1 and #3 of harness end of connector is 5±0.5 Open circuit in harness V. YES between MC and Check fi voltage · Key switch: ON pressure sensor (terminal between terminal #1 #3). of harness end of Switch pressure sensor NO connector in pressure with other pressure sensor and machine Open circuit in harness sensor and retry. is specification. between MC and Check if fault code NO pressure sensor (terminal · Key switch: ON disappears. #1). · Refer to the table upward. Faulty pressure sensor. YES YES Faulty harness between MC and pressure sensor. Faulty pressure sensor.