hitachi — PREPARATION FOR PERFORMANCE TESTS

TROUBLESHOOTING / Troubleshooting A MC FAULT CODE 11400 IMPORTANT: In case switching the connector in solenoid valve and performing the diagnosing, check for continuity in the solenoid before switching. When the connector is switched and the engine starts with the solenoid shorted, normal solenoid valve and MC may be damaged. Pump control solenoid valve: 17.5 Ω at 20 ° C 4-spool solenoid valve unit: 18.5 Ω at 20 ° C control solenoid valve.

· Between terminal #A16 of connector MC-A in MC and terminal #2 of connector in pump2 control solenoid valve Connector (Harness end of connector viewed from the open side) MC Connector MC-A Pump 2 Control Solenoid Valve T1J1-05-06-003 T183-05-04-008 T5-6-71 Fault Code Trouble Cause 11400-3 Abnormal Feedback High Current of Pump 2 Control Solenoid Valve Current: Higher than 920 mA 11400-4 Abnormal Feedback Low Current of Pump 2 Control Solenoid Valve Current: Less than 56 mA Switch connectors of Faulty pump2 control pump2 control solenoid NO solenoid valve. valve and control solenoid valve. YES Check if fault code in torque control solenoid Faulty MC. valve is displayed.

YES Check for continuity in harness between MC and pump2 control solenoid valve. · Between terminal #A22 of connector MC-A in MC and terminal #1 of Open circuit in harness. connector in pump2 NO Open circuit in harness. NO #A16 #A22