hitachi — PREPARATION FOR PERFORMANCE TESTS

TROUBLESHOOTING / Troubleshooting A MC FAULT CODE 11402 IMPORTANT: In case switching the connector in solenoid valve and performing the diagnosing, check for continuity in the solenoid before switching. When the connector is switched and the engine starts with the solenoid shorted, normal solenoid valve and MC may be damaged. Pump control solenoid valve: 17.5 Ω at 20 ° C 4-spool solenoid valve unit: 18.5 Ω at 20 ° C · Between terminal #A3 of connector MC-A in MC and terminal #2 of connector in solenoid valve unit (SF) (digging regeneration).

Connector (Harness end of connector viewed from the open side) MC Connector MC-A Solenoid Valve Unit (SF) (Digging Regeneration) T1V1-05-04-003 T183-05-04-008 T5-6-72 Fault Code Trouble Cause 11402-3 Abnormal Feedback High Current of Solenoid Valve Unit (SF) (Digging Regeneration) Current: Higher than 920mA 11402-4 Abnormal Feedback Low Current of Solenoid Valve Unit (SF) (Digging Regeneration) Current: Less than 56 mA Switch connectors of solenoid valve unit (SF) Faulty solenoid valve unit YES (digging regeneration) (SF) (digging and other solenoid regeneration). YES valve unit (SC, SG or SI). Check if fault code in Faulty MC.

switched solenoid valve Check for continuity in NO unit is displayed. harness between MC and solenoid valve unit (SF) · After switching (digging regeneration). connectors, operate combined operation of · Between terminal #A20 boom lower and bucket of connector MC-A in or arm, and check by MC and terminal #1 of using Dr. ZX. connector in solenoid Open circuit in harness. valve unit (SF) (digging NO Open circuit in harness. NO #A3 #A20