TROUBLESHOOTING / Troubleshooting A MC FAULT CODE 11404 IMPORTANT: In case switching the connector in solenoid valve and performing the diagnosing, check for continuity in the solenoid before switching. When the connector is switched and the engine starts with the solenoid shorted, normal solenoid valve and MC may be damaged. Pump control solenoid valve: 17.5 Ω at 20 ° C 4-spool solenoid valve unit: 18.5 Ω at 20 ° C valve unit (SG) (relief pressure control). · Between terminal #A7 of connector MC-A in MC and terminal #2 of connector in solenoid valve unit (SG) (relief pressure control).
Connector (Harness end of connector viewed from the open side) MC Connector MC-A Solenoid Valve Unit (SG) (Relief Pressure Control) #A23 T1V1-05-04-003 T183-05-04-008 T5-6-73 Fault Code Trouble Cause 11404-3 Abnormal Feedback High Current of Solenoid Valve Unit (SG) (Relief Pressure Control) Current: Higher than 920mA 11404-4 Abnormal Feedback Low Current of Solenoid Valve Unit (SG) (Relief Pressure Control) Current: Less than 56 mA Switch connectors of Faulty solenoid valve unit solenoid valve unit (SG) YES (SG) (relief pressure (relief pressure control) control). YES and other solenoid valve unit (SF, SC or SI). Faulty MC.
Check if fault code in switched solenoid valve NO Check for continuity in unit is displayed. harness between MC and solenoid valve unit · After switching (SG) (relief pressure connectors, operate control). boom raise relieved, and check by using Dr. · Between terminal #A23 ZX. of connector MC-A in Open circuit in harness. MC and terminal #1 of NO connector in solenoid Faulty solenoid valve unit (SG) (relief pressure control). Open circuit in harness. NO #A7