hitachi — PREPARATION FOR PERFORMANCE TESTS

TROUBLESHOOTING / Troubleshooting A MC FAULT CODE 11405 IMPORTANT: In case switching the connector in solenoid valve and performing the diagnosing, check for continuity in the solenoid before switching. When the connector is switched and the engine starts with the solenoid shorted, normal solenoid valve and MC may be damaged. Pump control solenoid valve: 17.5 Ω at 20 ° C 4-spool solenoid valve unit: 18.5 Ω valve unit (SI) (travel motor fast speed selection). · Between terminal #A17 of connector MC-A in MC and terminal #2 of connector in solenoid valve unit (SI) (travel motor fast speed selection).

Connector (Harness end of connector viewed from the open side) MC Connector MC-A Solenoid Valve Unit (SI) (Travel Motor Fast Speed Selection) #A11 T1V1-05-04-003 T183-05-04-008 T5-6-74 Fault Code Trouble Cause 11405-3 Abnormal Feedback High Current of Solenoid Valve Unit (SI) (Travel Motor Fast Speed Selection) Current: Higher than 920mA 11405-4 Abnormal Feedback Low Current of Solenoid Valve Unit (SI) (Travel Motor Fast Speed Selection) Current: Less than 56 mA Switch connectors of Faulty solenoid valve unit solenoid valve unit (SI) YES (SI) (travel motor fast (travel motor fast speed speed selection). selection) and other YES solenoid valve unit (SF, SC or SG).

Check if fault code in Faulty MC. switched solenoid valve NO Check for continuity in unit is displayed. harness between MC and solenoid valve unit · After switching (SI) (travel motor fast connectors, turn travel speed selection). mode switch to FAST, and check by using Dr. · Between terminal #A11 ZX. of connector MC-A in MC and terminal #1 of Open circuit in harness. connector in solenoid NO Open circuit in harness. NO #A17