TROUBLESHOOTING / Troubleshooting A MC FAULT CODE 11410 IMPORTANT: In case switching the connector in solenoid valve and performing the diagnosing, check for continuity in the solenoid before switching. When the connector is switched and the engine starts with the solenoid shorted, normal solenoid valve and MC may be damaged. Pump control solenoid valve: 17.5 Ω at 20 ° C 4-spool solenoid valve unit: 18.5 Ω at 20 ° C control solenoid valve. · Between terminal #A16 of connector MC-A in MC and terminal #2 of connector in pump 1 control solenoid valve.
Connector (Harness end of connector viewed from the open side) Pump 1 Control Solenoid Valve MC Connector MC-A T1J1-05-06-003 T183-05-04-008 T5-6-75 Fault Code Trouble Cause 11410-3 Abnormal Feedback High Current of Pump 1 Control Solenoid Valve Current: Higher than 920mA 11410-4 Abnormal Feedback Low Current of Pump 1 Control Solenoid Valve Current: Less than 56 mA Switch connectors of YES Faulty pump 1 control pump 1 control solenoid solenoid valve. valve and pump 2 control YES solenoid valve. Check if fault code in torque control solenoid Faulty MC. valve is displayed. NO Check for continuity in harness between MC and pump 1 control solenoid valve.
· Between terminal #A22 of connector MC-A in MC and terminal #1 of Open circuit in harness. connector in pump 1 NO Switch connectors of pump 1 control solenoid valve and pump 2 control solenoid valve. YES Faulty pump 1 control solenoid valve. Check if fault code in torque control solenoid valve is displayed. Open circuit in harness. NO #A16 #A22