TROUBLESHOOTING / Troubleshooting A MC FAULT CODE 11412 IMPORTANT: In case switching the connector in solenoid valve and performing the diagnosing, check for continuity in the solenoid before switching. When the connector is switched and the engine starts with the solenoid shorted, normal solenoid valve and MC may be damaged. Pump control solenoid valve: 17.5 Ω at 20 ° C 4-spool solenoid valve unit: 18.5 Ω at 20 ° C control solenoid valve. · Between terminal #A15 of connector MC-A in MC and terminal #2 of connector in fan pump control solenoid valve.
Connector (Harness end of connector viewed from the open side) Fan Pump Control Solenoid Valve MC Connector MC-A T1J1-05-06-003 T183-05-04-008 T5-6-76 Fault Code Trouble Cause 11412-3 Abnormal Feedback High Current of Fan Pump Control Solenoid Valve Current: Higher than 920mA 11412-4 Abnormal Feedback Low Current of Fan Pump Control Solenoid Valve Current: Less than 56 mA Switch connectors of fan YES Faulty fan pump control pump control solenoid solenoid valve. valve and pump 2 control YES solenoid valve. Check if fault code in torque control solenoid Faulty MC. valve is displayed. NO Check for continuity in harness between MC and maximum pump 1 flow rate limit control solenoid valve.
· Between terminal #A9 of connector MC-A in MC and terminal #1 of Open circuit in harness. connector in fan pump NO Switch connectors of fan pump control solenoid valve and pump 2 control solenoid valve. YES Faulty fan pump control solenoid valve. Check if fault code in torque control solenoid valve is displayed. Open circuit in harness. NO #A15 #A9